+55 (11) 3488-8787
Loading
Clique e conheça a página da Softbrasil no Facebook Clique e conheça nosso perfil no Twitter Acesse nosso Canal no Youtube Faça parte de nossa Rede no Linkedin

IES-2008F-67

IES-2208F-67

8 10/100TX + 2 100FX M12 / IP-67 Managed Industrial Switch

  • Pro-Ring II :Pro-Ring (Legacy-Ring) and Pro-Ring II system (Pro-Ring II , Advanced Dual Homing, Daisy Couple Ring and Multi Couple Ring Topology)
  • Provides M12 connector with IP-66/67 rated protection
  • Wide Operating Temperature from -40°C to 75°C
  • Support with L-Key(M12) for easy maintenance


    OVERVIEW

    Lantech IES-2208F-67 is an 8 10/100 Base-TX + 2 100FX with M12-connctor Managed Industrial Switch for IP66/67 rated protection. The full SNMP management features are including QoS for 4 queues, 801.q VLAN, IGMP snooping and query mode as well as SNTP and SMTP. The PTP(Precision Time Protocol) client will be future supported.future supported.

    Equipped with DC 9V~56V / DC-9V~-56V power input design, Lantech IES-2208F-67 can support redundant power supply input to ensure power runtime.  It also supports relay contact to connect with alarm system, which can immediately notify of power failure and/or port down events. In case of events, Lantech IES-2208F-67 will immediately send an email to pre-defined addresses and send trap to stations.emailto pre-defined addresses and send trap to stations.

    Lantech IES-2208F-67 supports our Pro-Ring (Legacy-Ring) and Pro-Ring II system. Pro-Ring(Legacy-Ring), an auto-recovery path within 10ms up to 250 Lantech Industrial Switches; Pro-Ring II is a new Ring mechanism for Lantech Industrial Switches in which it eliminates the need to pre-set the Master switch in previous Pro-Ring and yet to protect the network by much secure topologies than ever. It works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier. Pro-Ring II can be backward compatible with old Pro-Ring by down-grading the Ring scheme to old one.

    IES-2208F-67 is designed to meet with critical network environment with IP67 enclosure and M12 connectors for protection against water and dust ingress. It has passed harsh environmental testing to comply with Industrial EMI and Safety standards. Besides 1.2KVA Hi-Pot abnormal test, it also passed stability testing such as Free fall, Shock, and Vibration. For a greater flexibility in application the IES-2208F-67 supports an extended operating temperature range from -40°C to 75°C.

    Lantech L-Key (M12) can be used to quickly configure the IES-2208F-67 on site without the need for an IP connection or notebook PC. Lantech IES-2208F-67 is an ideal choice for critical industrial environments such as smelters, crusher plants, open cut mines etc.



Certificados

 8-port 10/100TX + 2-port 100FX Managed Industrial Switch with M12 connectors and IP66/67 rated protection

 Back-plane (Switching Fabric): 5.6Gbps

 1Mbits Packet Buffer

 IGMP with Snooping and Query mode for Multi Media Application

 8K MAC address table

 Redundant Power Design with wide DC 9V~56V/ DC -9~-56Vinput

 IEEE 802.1d Spanning Tree & IEEE 802.1w RSTP

 Port Based VLAN, 802.1Q Tag VLAN, GVRP

 Pro-Ring II

  • Pro-Ring (Legacy-Ring) and Pro-Ring II system (Pro-Ring II , Advanced Dual Homing, Daisy Couple Ring and Multi Couple Ring Topology).
  • Provide redundant backup feature and the recovery time below 10ms.

 Port Trunk with LACP

 Supports IEEE 802.1ab LLDP

 IEEE 802.1p Class of Service, per port 4 priority queues

 Port base, Tag Base and Type of Service Priority

 Supports Ingress Packet Filter and Egress Rate Limit

 Supports Broadcast/Multicast Packet Filter Control

 Port Mirror: Monitor traffic in switched networks

 System Log Server/Client

 Security

  • Port Security: MAC address entries/Filter
  • IP Security: IP address security management to prevent unauthorized intruder
  • Login Security: IEEE802.1X/RADIUS

 SNMP Trap

  • Device cold start, Power status, Authentication failure, Pro-Ring topology changed, Port Link up/Link down, port events

 Relay Alarm Output System Events

 IGMP with Query mode for Multi Media Application

 TFTP Firmware Update and System Configure Restore/Backup

Hardware Specification

IEEE Standard

IEEE802.3 10Base-T Ethernet 
IEEE802.3u 100Base-TX 
IEEE802.3x Flow Control and Back Pressure 
IEEE802.3ad Port trunk with LACP 
IEEE802.3af Power over Ethernet
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree 
IEEE802.1p Class of Service 
IEEE802.1Q VLAN Tag 
IEEE802.1x User Authentication (Radius) 
IEEE802.1ab LLDP
IEEE1588 PTP client*

Switch Architecture

Back-plane (Switching Fabric): 5.6Gbps

Transfer Rate

14,880pps for Ethernet port 
148,800pps for Fast Ethernet port

Packet Buffer

1Mbits

MAC Address

8K MAC address table

Connector

10/100TX: 8 x M12 4-pole D-coded with auto MDI/MDI-X function
2 100FX/LC (LX/SX) connectors
RS-232 connector: 1 x M12 8-pole A-coded

Network Cable

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5, 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable
EIA/TIA-568 100-ohm (100m)

Optical Cable

Multi-mode: 50/125um~62.5/125um
Single mode: 9/125um
Available distance: 0.5km (Multi-mode)/10km (Single-mode)
Wavelength: 1310nm (Multi-mode/Single-mode)

Protocol

CSMA/CD

LED

Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red), R-Master (Green)
Ethernet: Link/Activity (Green, Fiber: Link/Activity (Green)

Power Supply

DC 9V~56V/DC -9V~-56V, Redundant power with M12 5-pole A-coded connector

Reserve polarity protection

Present

Overload current protection

Present

Power Consumption

14W

Operating Temperature

-40°C~75°C / -40°F~167°F

Storage Temperature

-40°C~85°C / -40°F~185°F

Operating Humidity

5% ~ 95% (Non-condensing)

Case Dimension

IP-67, 193mm (W) x 176mm (H) x 62.5mm (D)

Weight

1630g

Installation

Wall mount design

EMI & EMS

FCC Class A, CE EN61000-4-2 (ESD), 
CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), 
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), 
CE EN61000-4-8, CE EN61000-6-2,
CE EN61000-6-4

Stability Testing

IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration)

Standard EN50155**

MTBF

320,420 hours

Warranty

1 year

Software Specification

Management

SNMP v1 v2c, v3/ Web/Telnet/CLI

SNMP MIB

RFC 1215 Traps MIB, RFC 1213 MIBII, 
RFC 1157 SNMP MIB, RFC 1493 Bridge MIB, 
RFC 2674 VLAN MIB, RFC 1643 EtherLike, 
RFC 1757 Rmon, RSTP MIB, Private MIB, PoE MIB,LLDP MIB

VLAN

Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP (256 Groups)

Port Trunk with LACP

LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk members

LLDP

Supports IEEE802.1ab LLDP, the advertising of the switch’s Identity and capabilities

Spanning Tree

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree

Pro-Ring II

Pro-Ring II :Pro-Ring (Legacy-Ring) and Pro-Ring II system (Pro-Ring II , Advanced Dual Homing, Daisy Couple Ring and Multi Couple Ring Topology) 
Provides redundant backup feature and the recovery time below 10ms for a ring of up to 250 switches

Quality of Service

The quality of service determined by port, Tag and IPv4 Type of service, IPv4/IPv6 Different Service

Class of Service

Supports IEEE802.1p class of service, per port provides 4 priority queues

Port Security

Supports 100 entries of MAC address for static MAC and another 100 for MAC filter

Port Mirror

Supports 3 mirroring types: "RX, TX and Both packet"

IGMP

Supports IGMP snooping v1,v2 
256 multicast groups and IGMP query

IP Security

Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.

Login Security

Supports IEEE802.1X Authentication/RADIUS

Flow Control

Supports Flow Control for Full-duplex and Back Pressure for Half-duplex

System Log

Supports System log record and remote system log server

SMTP

Supports SMTP Server and 6 e-mail accounts for receiving event alert

SNTP

Supports SNTP to synchronize system clock in Internet

Bandwidth Control

Support ingress packet filter and egress packet limit
The egress rate control supports all of packet type and the limit rates are 100K~102400Kbps(10/100), 
Ingress filter packet type combination rules are
Broadcast/Multicast/Unknown Unicast packet,
Broadcast/Multicast packet, Broadcast packet only and all of packet. The packet filter rate can be set from 100K~102400Kbps(10/100),

Relay Alarm

Provides one relay output for port breakdown, power fail and alarm
Alarm Relay current carry ability: 1A @ DC24V

SNMP Trap

Up to 3 Trap stations
Cold start, Port link up, Port link down, Authentication Failure, Private Trap for power status, Port Alarm configuration, Fault alarm, Pro-Ring topology change

DHCP

Provides DHCP Client/ DHCP Server/ IP Relay functions

DNS

Provides DNS client feature and support Primary and Secondary DNS server

Firmware Update

Supports TFTP firmware update, TFTP backup and restore.

Configuration upload and download

Supports binary format configuration file for system quick installation


  • IES-2208F-67-MM…………....….….......P/N: 8360-480
    8 10/100TX + 2 100FX (MM, 2KM) IP67 rated Managed Industrial Switch w/M12 connectors
  • IES-2208F-67-SM…………....….….......P/N: 8360-481
    8 10/100TX + 2 100FX (SM, 30KM) IP67 rated Managed Industrial Switch w/M12 connectors

 

OPTIONAL ACCESSORIES

DIN Rail Power
  • AD1048-24FS
    24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)
  • AD1024-24F
    24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)
  • AD1240-48S
    48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C 
    (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
  • AD1120-48F
    48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)

 

M12 Connector / Cable

  • ECON120005MM
    5 Pin M12 Power Male Connector
  • ECON120004FF
    4 Pin M12 RJ45 Female Connector
  • ECON120003FF
    3 Pin M12 Relay Female Connector
  • ECAB125030F0
    5 Pin M12 Power Female 3M Cable
  • ECAB124030MJ
    4 Pin M12 RJ45 Male 3M Cable
  • ECAB123030M0
    3 Pin M12 Relay Male 3M Cable
  • ECAB124030MM
    4 Pin M12 Male-Male 3M Cable
d-ies-2208f-67.pdfLink para download
m-ies-2208f-67.pdfLink para download
ies-2208f-67_v100k501.binLink para download